2014 ACEEE Summer Study: Monitoring the Real World Usage of Network Connected Products
This paper proposes recommendations to policy makers based on a real time data collection exercise carried out in the UK, to analyze the “real world usage” of network connected devices. The paper also maps out how to replicate the project approach and methodology in the US and other regions, to determine whether similar opportunities exist in other areas.
New Discussion Paper Assesses Alignment of EU Test Procedures and S&L Regulations
Developing test procedures to measure the energy performance of products is fundamental to delivering the energy saving potential from setting energy performance standards and labeling requirements. And yet such test procedures are not always sufficiently well aligned, in time and in substance, with the policy requirement they are intended to support. In this paper the effectiveness of the EU approach to developing such standards is assessed and a portfolio of options for improving the alignment between test procedures and EU Ecodesign and Energy Labelling requirements are outlined. The intention of the paper is to help inform the discussion in Europe, for example in the context of the ongoing simultaneous review of the EU’s Ecodesign and Energy Labelling Directives during 2014 and 2015.
This paper was written for CLASP by Edouard Toulouse, an independent consultant and long time participant in the regulatory process in Europe.
Benchmarking China Clothes Washer Test Procedures against those used in the EU
Clothes washers are an important product, as households in China increasingly consider them a necessity. As income levels rise in rural areas, the demand for washing machines continues to grow. It is estimated that clothes washers consume approximately 15 TWh of energy per year in 2030 – enough to power more than 11 million of Chinese homes for a year. Such projections demonstrate the need to address the energy efficiency and overall consumption of washing machines.
Since China’s first minimum energy performance standard for domestic clothes washers was issued in 2004, rapid technology development and government aid through financial incentives have significantly driven up the energy efficiency levels of products sold on the Chinese market. The 2004 standard has not kept pace with market shifts, and a more stringent standard is required to continue pushing the clothes washer market towards higher energy efficiency.
In 2012, CLASP and Consumer Research Associates partnered to conduct a benchmarking comparison of clothes washer energy efficiency performance, policies, and test methods. The main objective was to assist the China National Institute of Standardization (CNIS) in revising efficiency requirements for future clothes washer energy performance standards in a transparent and technically valid manner that is consistent with international best practices.
This study also provided CNIS with an opportunity to compare Chinese test methodology, laboratory practices and EE policies with those in the EU. The results of the comparison will assist CNIS in determining whether the adoption of an international standard or test method could become appropriate for China in the future.
Due to the absence of reliable data about the Chinese market, a benchmarking comparison of clothes washers between China and other economies has not been undertaken previously. For the purposes of this study, CLASP mapped the Chinese and EU clothes washer markets, selected representative machines, and conducted cross-market testing for the first time. At CNIS’ request, CLASP also provided training to CNIS testing staff to conduct testing based on EU methodology so that it could be replicated in CNIS’ clothes washer test laboratory. A training component was therefore included in the testing phase for this study.
The comparison of energy efficiency labeling specifications in both the Chinese and EU markets for the same washer samples demonstrates two things:
- Firstly, it shows that there is a close correlation between the test standards being applied in both markets for front-loading washers. These results give CNIS confidence that adopting test methods used international or in the EU would be likely to be acceptable to domestic manufacturers.
- Secondly, the comparison demonstrates that China’s current EE labeling thresholds for front-loading washers are on par with those in the EU. It is important to note, however, that front-loading washers only account for about 32% of China’s clothes washer market.
The Practical Scope for Reducing Air Conditioning Energy Consumption in Europe: Policy Opportunities and Priorities
This paper summarises the results of “Study to assess barriers and opportunities to improving energy efficiency in cooling appliances/systems”, which was carried out by the Building Research Establishment and funded by CLASP. The purpose of the study was to contribute to the development of relevant policy by identifying and quantifying the potential impact of possible measures to reduce the energy consumption of air conditioning in Europe over a ten-year period, relative to a business-as-usual scenario.
Many of the policy measures relate to the performance of products and equipment, but there is also considerable potential in the areas of load reduction and more effective operation and management of systems. The analysis focuses on quantified realisable savings that reflect technically-feasible measures whose rate of introduction is constrained by the replacement rate of air conditioning systems and appliances, refurbishment rates of buildings and different levels of ambition for performance regulations placed on air conditioning equipment and systems. It is disaggregated by country, but this paper concentrates on results for Europe as a whole.
The measures that offer the largest realisable savings formed the basis for recommendations for policy measures, often using existing policy instruments. These measures fall into two groups relating, on the one hand, to policies that impact directly on technical requirements for systems and products and, on the other hand, to those that do not. The second group includes policy measures to incentivize effective operation of buildings and systems, and to influence take-up rates for high-efficiency products. Additional recommendations relate to the application of policy: consistency of approach between instruments; choice of application at national or European level. The report also identifies areas where further work is needed to improve the robustness of studies similar to this one.
More detailed results and information about the study can be found at http://www.bre.co.uk/searchres…
Authors
Roger Hitchin, Christine Pout and David Butler of the Building Research Establishment, UK
The New Energy Label: Assessing Consumer Comprehension and Effectiveness as a Market Transformation Tool
The EU’s energy labelling programme dates back to the mid-1990s. The design of the label was the first leading energy label design to be informed by consumer research and this guided the adoption of key elements of the design. This iconic design was applied to refrigerators, then other domestic appliances and has since been adopted in EU energy labels for lighting, cars and buildings. Many countries around the world have adopted key elements of the design.
In recent years, the design of the label for household refrigerators, washing machines and dishwashers has been modified to include the introduction of additional efficiency classes up to the A+++ class. There has also been a move away from a two-part label with a language specific background to a single language-neutral label that is the same across the whole EU. Given such significant changes and the active debate which preceded them, it is important to establish how well the revised labels work with consumers to assess their likely energy saving impact. This paper presents the preliminary findings of a comprehensive consumer research study which does exactly this.
Consumer focus groups and questionnaires were conducted in ten cities across the EU and were complemented by three sets of in-depth interviews held in London, Prague and Paris. The methodology involved a mixture of qualitative and quantitative market research techniques that was designed to extract the maximum amount of information in an unbiased and non-leading way.
The research was carried out by Navigant Consulting and funded by CLASP. Sowatt and SEVEn also contributed to the research in the data collection phase.
Assessing Consumer Comprehension of the EU Energy Label
Impact assessments of European equipment energy efficiency policy measures have historically found that the EU energy label has been the most influential instrument in driving forward the energy efficiency of European equipment markets. It is therefore crucial to assess the label’s continuing effectiveness whenever changes are made to its design and implementation.

In 2010, the original Energy Labelling Directive was recast. Its scope of applicability was broadened, and many existing labels – specifically those applying to refrigerators and freezers, washing machines, and dishwashers – were redesigned.
This discussion centred on whether it would be better to re-grade the old A-to-G energy efficiency scale, or to add new higher efficiency classes above class “A.” Ultimately, a decision was made to add higher efficiency classes (A+, A++, and A+++) and to adjust the label to be language-neutral across all Member States, among other changes.
This analysis, conducted by Navigant Consulting for CLASP, examines the effectiveness of the new label design in supporting consumers to make informed choices about the energy efficiency of appliances during purchase. To this end, Navigant conducted ten consumer focus groups and 30 in-depth interviews across ten cities in the EU to assess how consumers use, understand, and are motivated by the new and revised labels.
The survey evidence clearly demonstrates that the new labels are generally appreciated and have a reasonably high level of comprehension thanks to the overall effectiveness of the label efficiency scale, use of color, efficiency classification, and energy consumption information. Most consumers were able to use the labels to correctly rank the efficiency of products; however, a significant minority had difficulty in doing this. Additionally, the assessment shows that while consumers comprehend both the A-G and the A+++-D efficiency scales, there is a very marked difference in the motivational effect of A as the top efficiency class compared to the A+++.
Based on the survey findings, the authors recommend the following measures, among others for specific aspects of the design, for the European Commission’s upcoming review of the labeling scheme:
- For future label revisions, consider re-grading the A-to-G efficiency scale in preference to adding more plus signs;
- Raise awareness that labeling is an EU scheme operated by the European Commission with support from Member States;
- Strengthen label comprehension through educational communication campaigns; and
- Test icon and other label element comprehension to ensure optimal understanding before deployment.
The study was produced for CLASP by Paul Waide and Rowan Watson of Navigant Consulting, Inc, with additional support from Millward Brown and SEVEn, with the assistance of SoWatt (France and Italy), Escan (Spain), KAPE (Poland), Öko-Institut (Germany), and EnEffect (Bulgaria).
LOT 2, Distribution and Power Transformers: Design Report on Large Power Transformers, 25 MVA, 63 MVA and 100 MVA
In support of the European Commission’s assessment of eco-design requirements for Distribution and Power Transformers, CLASP has undertaken this study investigating the relationship between the manufacturer’s selling price and efficiency for large power transformers.
This is the third transformer design report prepared by CLASP for this regulatory proceeding (i.e. DG Enterprise Lot 2: Distribution and Power Transformers), the others being a report on three oil-immersed transformers in August 2010 and a report on two cast-coil dry-type transformers in March 2011.
This report presents the design results of three large power transformers:
- 25 MVA three-phase oil-immersed, 150/20 kV with on-load tap changer
- 100 MVA three-phase oil-immersed, 220/23.8 kV with on-load tap changer
- 63 MVA three-phase oil-immersed, 150/20 kV with on-load tap changer
Understanding how the price of transformers increases as the efficiency improves is important because it enables an accurate assessment of life-cycle costs and associated payback periods. Generally, a transformer becomes more expensive as efficiency improves because it is incorporating either more material and/or better quality materials.
The designs presented in this report were prepared by Professor Antonio Bossi and Professor Angelo Baggini. The megavolt-ampere (MVA) ratings, voltages and other design parameters were selected to try and be representative of models installed in Europe.
Estimating Additional Energy Savings in the EU
Analysis by CLASP identified an additional 40-70 TWh of energy saving per annum by 2030 from eleven existing ecodesign and energy labeling regulations covering seven product groups. All eleven regulations were scheduled for review by the end of 2014.
The discussion paper was intended, with the support of eceee, as a contribution to the evidence base for the reviews of – and to help prioritize efforts on – energy-related product policy in the EU. CLASP and eceee hoped that the paper will prove of value to all stakeholders in the process and of interest to the wider energy efficiency community.
The paper estimates the potential additional energy savings from revisions to the EU’s ecodesign and energy labeling regulations on: household refrigerators, external power supplies, household washing machines, household dishwashers, tertiary lighting, household lighting and simple set-top boxes. Televisions are not included as the review process of existing regulations on televisions was already underway.
The analysis shows that, of the seven product groups, tertiary and household lighting together with household refrigerators continue to offer the greatest potential for energy savings.
The paper lays out illustrative policy scenarios for each product group appropriate to their technological progress. The scenarios are based on a high, medium, and low level of ambition. An economic assessment of technologies is not included in the scope of the paper, as it was prepared in a relatively short period of time. Instead, policy scenarios are informed by the scale of increases and timing of existing regulations, in addition to the assessment of technological development since the adoption of those regulations.
The Commission set out ambitious plans for energy related product policy for the period 2012-2014. CLASP and eceee hope that the discussion paper will be of use to the Commission, Member States and stakeholders in charting the way forward.
In particular, the analysis will help:
- Reduce the amount of time taken for any subsequent analysis in support of the reviews;
- Identify the most important product groups in energy saving terms;
- Identify the amount of energy that can be saved from revisions in addition to what is delivered by the regulations as they are;
- Prioritize the overall workload.
International Comparison of Product Certification and Verification Methods for Appliances 21-NOV-2012
The International Comparison of Product Certification and Verification Methods for Appliances study endeavors to:
- Review international best practices for product certification and verification as they relate to the enforcement of appliance standards and labeling programs in the U.S., E.U., Australia, Japan, Canada, and China; and,
- Provide recommendations to the Chinese government for the implementation of improved certification processes related to their mandatory standards and labeling program so as to increase compliance rates and energy savings potential.
Enforcement of appliance standards and consumer trust in appliance labeling are important foundations in the development of a more energy efficient economy. Product certification and verification increase compliance rates, which in turn increase both energy savings and consumer trust.
Practices for product certification and verification vary across the world, with some programs focusing solely on either certification or verification (such as in Australia and Canada) and other programs focusing on both (such as ENERGY STAR in the U.S.). Accreditation practices for testing laboratories and certification bodies also vary, with some appliance standards and labeling programs building databases to house all information on products and compliance.
The number of products covered by China’s mandatory standards program and labeling program has rapidly increased in recent years up to 44 products and 23 products, respectively. The Chinese government is currently seeking to improve the compliance rate for these products without reinventing its current organizational structure.
Based on a review of international practices in product certification and verification, the authors of this study offer the following recommendations to the Chinese government in the development of a more robust MV&E system:
- Organize certification bodies.
- Mandate certification process.
- Allow witness testing.
- Adapt from international standards.
- Standardize verification testing.
Introducing third party product certification and verification for the Chinese government’s mandatory standards and labeling programs has the potential to significantly improve compliance levels without heavy administrative burden.
Scoping Study for Commercial Refrigeration Equipment Mapping and Benchmarking Project
CLASP completed a cooling study in 2011, the first in a series intended to provide an international comparison of energy efficiency performance and policy measures for various appliances. The objectives of these studies are to lay the foundation for strong and comparable energy performance requirements at the global level and to pull the market towards higher levels of efficiency.
In order to maximize efficiency in its studies, CLASP has conducted a scoping study in partnership with Klinckenberg Consultants and Puddle Consultancy to define the work that will be needed for the benchmarking of commercial refrigeration equipment – these include beverage vending machines, walk-in coolers, and reach-in coolers. The study covers the following countries and economies: Australia, Canada, Denmark, European Union, Italy, Japan, Korea, New Zealand, South Africa, United Kingdom, and the USA (Federal, California, Washington State).
Mapping and Benchmarking projects can be challenging, and it is often not easy to find an approach that results in information that is directly beneficial to policy makers and program managers in a variety of countries, all at a different stage of development of their S&L policies. Most mapping and benchmarking projects have also experienced challenges due to incomparability of products in different parts of the world, different approaches to testing and lack of or unavailability of critical data.
This report describes the findings of the scoping study. It includes a summary report, which provides an overview of product definitions, main test procedures and comparability issues for the commercial refrigeration products covered, as well as an overview of the needs identified by S&L program managers in various countries. The report further includes three sections providing detailed information on Reach-in coolers (Section A), Cold vending machines (Section B), and Walk-in cold rooms (Section C).